Article ID: 000099392 Content Type: Troubleshooting Last Reviewed: 08/02/2024

Why is a remote fault insertion failure seen for a 10G using the F-Tile Ethernet FPGA Hard IP not reaching the sender when the sender’s transmitter path is broken?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® Prime Pro Edition Software version 24.1 and 24.2, the F-Tile Ethernet FPGA Hard IP shows remote fault not reaching the sender when the sender’s transmitter path is broken.

    This problem is caused by the dependence of remote fault insertion on local fault Hard IP and Soft Reset Controller(SRC) RX operational mode.

     

    Resolution

    The workaround is to trigger the remote fault insertion only when the SRC RX operational mode is changed. 

    This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs