Article ID: 000099392 Content Type: Troubleshooting Last Reviewed: 06/13/2025

Why is a remote fault insertion failure seen for a 10G using the F-Tile Ethernet FPGA Hard IP, not reaching the sender when the sender’s transmitter path is broken?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime Pro Edition Software version 24.1 and 24.2, the F-Tile Ethernet FPGA Hard IP shows remote fault not reaching the sender when the sender’s transmitter path is broken.

This problem is caused by the dependence of remote fault insertion on local fault Hard IP and Soft Reset Controller(SRC) RX operational mode.

 

Resolution

The workaround is only to trigger the remote fault insertion when the SRC RX operational mode is changed. 

This problem is fixed beginning with the Quartus® Prime Pro Edition software version 24.2.