Why do I see the locked-to-reference (LTR) and locked-to-data (LTD) signals of the RX GTS transceiver toggling when I apply a reset during user mode?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime Pro Edition Software version 24.2, when the RX adaptation mode is set to manual mode, the CDR LTR and LTD status signal might toggle when you apply a reset during user mode. 

 

Resolution

There is no workaround in the Quartus® Prime Pro Edition Software version 24.2 and earlier.

You need to reconfigure the device to overcome the problem and ensure the correct functionality of the GTS Transceiver.

This problem is fixed beginning with the Quartus® Prime Pro Edition software version 24.3.