Article ID: 000098827 Content Type: Error Messages Last Reviewed: 06/12/2024

Error-[PE_CDB] Corrupted data_block. Checksum did not match for data_block in file

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

This error may occur when calling the Quartus® EDA Simulation Library Compiler using a 32-bit version of the Synopsys VCS* simulator in the Quartus® Prime Pro Edition Software version 24.1 and earlier. 

Resolution

Synopsys VCS* compilation must be run with 64-bit support. This error can be fixed with either of the following steps:

  • Add the "-full64" flag to the command line, some Design Examples do this by default.
  • Set the VCS_TARGET_ARCH appropriately, for example to "linux64" or "suse64".

Related Products

This article applies to 1 products

Intel® Programmable Devices

1