Article ID: 000098757 Content Type: Error Messages Last Reviewed: 06/05/2024

Why does IP Upgrade fail on a composed IP that includes the discontinued Nios® II processor IP in future Quartus® Prime Software?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Nios® II Processor
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In the Quartus® Prime Pro Edition Software version 24.1, when migrating a composed IP that contains the discontinued Nios® II processor from the previous software version, the IP Upgrade feature reports the following error:

    “IP component no longer supported. Compilation of IP not supported in current software version.”

    This problem is due to the discontinued Nios® II processor.

     

     

    Resolution

    Workaround:

    Recommended action is to implement Nios® V processor IPs with equivalent functions in a new composed IP.

    Alternatively, add the following property in the *hw.tcl of the existing composed IP,

    set_module_property SUPPORTED_EOL_SUB_IPS {altera_nios2_gen2}

    The discontinued Nios® II processor IP core is render unavailable in the Quartus® Prime IP Catalog after the Last Time Shipments. Interested parties are encouraged to refer to the Nios II Processor Product Discontinuation Notice (PDN2312).