Description
No. You can use only 18_io_d8s1_sdm_lv for SDM output in the Stratix® 10 IBIS model.
In the Stratix® 10 IBIS model, there is the model selector of 18_io_sdm_lv_ms for SDM output. The model selector has multiple models. However, the drive strength, the slew rate, or the on-chip termination can't be changed in SDM output.
[Model Selector] 18_io_sdm_lv_ms
| 1.8 V
18_io_r50_sdm_lv Series 50 Ohm without Calibration, Slew Rate: FAST
18_io_d2s1_sdm_lv 2mA, Slew Rate: FAST
18_io_d4s1_sdm_lv 4mA, Slew Rate: FAST
18_io_d6s1_sdm_lv 6mA, Slew Rate: FAST
18_io_d8s1_sdm_lv 8mA, Slew Rate: FAST
18_io_d10s1_sdm_lv 10mA, Slew Rate: FAST
18_io_d12s1_sdm_lv 12mA, Slew Rate: FAST
18_io_d16s1_sdm_lv 16mA, Slew Rate: FAST
18_io_r25_sdm_lv Series 25 Ohm without Calibration, Slew Rate: FAST
18_io_d2s0_sdm_lv 2mA, Slew Rate: SLOW
18_io_d4s0_sdm_lv 4mA, Slew Rate: SLOW
18_io_d6s0_sdm_lv 6mA, Slew Rate: SLOW
18_io_d8s0_sdm_lv 8mA, Slew Rate: SLOW
18_io_d10s0_sdm_lv 10mA, Slew Rate: SLOW
18_io_d12s0_sdm_lv 12mA, Slew Rate: SLOW
18_io_d16s0_sdm_lv 16mA, Slew Rate: SLOW
Resolution
Use 18_io_d8s1_sdm_lv and ignore the other models in the model selector of 18_io_sdm_lv_ms.