Article ID: 000098723 Content Type: Error Messages Last Reviewed: 04/25/2024

Error(24438): The Quartus® Prime Software does not support HPS to be connected to both EMIF interface and HBM interface for Agilex™ device. Disconnect either HPS-EMIF or HPS-HBM

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In Quartus® Prime Pro Edition Software version 24.1, you may encounter the following error during the Synthesis stage when running an EMIF IP for HPS and HBM2E IP design with the "HPS boot from HBM2E" setting disabled:

     

    Error(24438): The Quartus Prime Software does not support HPS to be connected to both EMIF interface and HBM interface for Agilex™ device. Disconnect either HPS-EMIF or HPS-HBM.

    Resolution

    To work around this error, remove or comment out the following assignment in the HBM .qip file(s):

     

    set_global_assignment -entity "ed_synth_hbm_fp_..." -library "hbm_fp_400" -name HPS_ISW_HBM "HPS_IO_HBM_CH_EN 1 HPS_IO_HBM_ECC_EN 0"