Article ID: 000098634 Content Type: Troubleshooting Last Reviewed: 12/02/2024

Why do I see the checker error during the simulation of Interlaken (2nd Generation) FPGA IP Design Example for VHDL variants targeting Agilex™ 7 devices with ModelSim SE 2023.4 or Questa*- FPGA Edition?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Interlaken (2nd Generation) Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    You may see the following error message during the simulation of the Interlaken (2nd Generation) FPGA IP Design Example for VHDL variants targeting Agilex™ 7 devices with ModelSim SE 2023.4 or Questa*- FPGA Edition.

     

    # ________________________________________________________________# 	 INFO: Start transmitting packets
    # __________________________________________________________
    # 
    # 
    # time:            329910000 checker error count          1
    # __________________________________________________________
    # 	 INFO: Stop transmitting packets
    # __________________________________________________________
    # 
    # 
    # __________________________________________________________
    # 	 INFO: Checking packets statistics
    # __________________________________________________________
    # 
    # 
    # time:            344203333 checker error count         25
    # 		 CRC24 errors reported:      0
    # 		 SOPs transmitted:         100
    # 		 EOPs transmitted:         100
    # 		 SOPs received:            100
    # 		 EOPs received:            100
    # 		 ECC error count:            0
    # __________________________________________________________
    # 	 INFO: Test FAILED 
    # 
    # __________________________________________________________
    
    Resolution

    To work around this problem, please use ModelSim SE 2023.2.

    This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs