Description
You may see the following error message during the simulation of the Interlaken (2nd Generation) FPGA IP Design Example for VHDL variants targeting Agilex™ 7 devices with ModelSim SE 2023.4 or Questa*- FPGA Edition.
# ________________________________________________________________# INFO: Start transmitting packets
# __________________________________________________________
#
#
# time: 329910000 checker error count 1
# __________________________________________________________
# INFO: Stop transmitting packets
# __________________________________________________________
#
#
# __________________________________________________________
# INFO: Checking packets statistics
# __________________________________________________________
#
#
# time: 344203333 checker error count 25
# CRC24 errors reported: 0
# SOPs transmitted: 100
# EOPs transmitted: 100
# SOPs received: 100
# EOPs received: 100
# ECC error count: 0
# __________________________________________________________
# INFO: Test FAILED
#
# __________________________________________________________
Resolution
To work around this problem, please use ModelSim SE 2023.2.
This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.