Article ID: 000098368 Content Type: Error Messages Last Reviewed: 12/04/2024

Error (24312): Intel Quartus Prime software detected that the pin placement in bank 3B_T has violated the Byte I/O Standard rule. Reassign pin location assignment according to the following user guides to comply with the restrictions.

Environment

  • Intel® Quartus® Prime Pro Edition
  • Interfaces
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    The error message shown below will be seen during the fitter compilation stage when using the Quartus® Prime Pro Edition Software version 24.1 when no location assignments have been implemented in the Design Example generated from the Agilex™ 5 MIPI D-PHY FPGA IP.

     

    Error (24312): Quartus Prime software detected that the pin placement in bank 3B_T has violated the Byte I/O Standard rule. Reassign pin location assignment according to the following user guides to comply with the restrictions.

    Info (24313): For MIPI design, review "Using the Remaining I/O Pin from Same Byte Location" as outlined in the Agilex™ 5 FPGA MIPI D-PHY IP User Guide.

                   

     

    Resolution

    To workaround this problem, provide a location assignment to at least one of the Agilex™ 5 MIPI D-PHY FPGA IP pins in the Design Example.