Due to a problem in the Quartus® II Software versions 13.0sp1 and earlier, you may see that the MIN_fast option can be selected in the Set Operating Conditions within the TimeQuest Timing Analyzer, even though the MIN_fast is not supported with MAX® 7000S, 7000AE, 7000B and 3000A devices.
If the user selects the MIN_fast option, it will generate the below error message:
ERROR: Values entered did not match any valid operating conditions. Available operating conditions are: Slow Model, Fast Model
Likewise, if the user enables the Enable multicorner timing analysis during compilation under Settings > Compilation Process Settings, the compilation will fail with the below error message:
Error (23035): Tcl error: ERROR: Values entered did not match any valid operating conditions. Available operating conditions are: Slow Model, Fast Model
The MIN_fast model is not supported with MAX® 7000S, 7000AE, 7000B and 3000A devices.
Use the other supported operating conditions available in the TimeQuest Timing Analyzer.