Article ID: 000097922 Content Type: Troubleshooting Last Reviewed: 03/05/2024

ERROR: Values entered did not match any valid operating conditions. Available operating conditions are: Slow Model, Fast Model

Environment

  • Quartus® II Software
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® II Software versions 13.0sp1 and earlier, you may see that the MIN_fast option can be selected in the Set Operating Conditions within the TimeQuest Timing Analyzer, even though the MIN_fast is not supported with MAX® 7000S, 7000AE, 7000B and 3000A devices.

    If the user selects the MIN_fast option, it will generate the below error message:
    ERROR: Values entered did not match any valid operating conditions. Available operating conditions are: Slow Model, Fast Model

    Likewise, if the user enables the Enable multicorner timing analysis during compilation under Settings > Compilation Process Settings, the compilation will fail with the below error message:
    Error (23035): Tcl error: ERROR: Values entered did not match any valid operating conditions. Available operating conditions are: Slow Model, Fast Model

    Resolution

    The MIN_fast model is not supported with MAX® 7000S, 7000AE, 7000B and 3000A devices. 

    Use the other supported operating conditions available in the TimeQuest Timing Analyzer.  

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices