Article ID: 000096311 Content Type: Troubleshooting Last Reviewed: 05/20/2024

Why is there no output data on o_tx_serial[1:0] pins when only hard reset is applied to F-Tile Ethernet FPGA Hard IP with the '50GE-2' variant?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime Pro Edition Software version 22.4 and onward, you may see no output data on o_tx_serial[1:0] pins, and o_tx_ready does not toggle when only hard reset [i_rst_n] is applied to F-Tile Ethernet FPGA Hard IP with '50GE-2' variant.

Resolution

To work around this problem in the Quartus® Prime Pro Edition Software version 22.4 and onward, apply i_tx_rst_n, i_rx_rst_n and csr_rst_n as well as i_rst_n.

This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.

Related Products

This article applies to 1 products

Intel Agilex® 7 FPGAs and SoC FPGAs

1