Article ID: 000095566 Content Type: Troubleshooting Last Reviewed: 06/27/2023

Why does configuration fail to recover after unsuccessful initial configuration using JTAG, Avalon-ST, or ASx4 configuration scheme on Intel Agilex® 7 M-Series devices?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In the Intel® Quartus® Prime Pro Edition Software version 23.2, you might observe intermittent failure to recover with a good image for JTAG, Avalon-ST, or ASx4 configuration scheme on Intel Agilex® 7 M-Series devices after an unsuccessful initial configuration with a corrupted image.  

     

     

    Resolution

    To work around this problem, power cycle Intel Agilex® 7 M-Series device and configure it with a good image.
    This problem is planned to be fixed in a future release of Intel® Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs