Article ID: 000095483 Content Type: Troubleshooting Last Reviewed: 06/21/2023

Warning: 18059 Ignored Maximum Fan-Out assignment

Environment

  • Intel® Quartus® Prime Standard Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Standard Edition Software version 20.1 and earlier, you may see this warning if the "maxfan" assignment is applied to a register that drives an input of an M20K block RAM.

     

     

    Resolution

    To work around this issue, perform one of the following options:

    1. Manually split the RAM into smaller blocks and feed each block with its own copy of the read and write address registers.
    2. Set a "dont_merge" attribute on each copy of the read and write address registers

    This problem is fixed beginning with the Intel Quartus® Prime Standard Edition Software version 21.1

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices