Description
Due to a problem in the Intel® Quartus® Prime Standard Edition Software version 20.1 and earlier, you may see this warning if the "maxfan" assignment is applied to a register that drives an input of an M20K block RAM.
Resolution
To work around this issue, perform one of the following options:
- Manually split the RAM into smaller blocks and feed each block with its own copy of the read and write address registers.
- Set a "dont_merge" attribute on each copy of the read and write address registers
This problem is fixed beginning with the Intel Quartus® Prime Standard Edition Software version 21.1