Article ID: 000094960 Content Type: Error Messages Last Reviewed: 05/18/2023

Why does in Intel® Quartus® Prime Pro Edition Software version 20.4, Intel Agilex® 7 DDR4 IP Traffic Generator 2.0 (TG2) Toolkit for the timeout or incorrect failure occur under the Configuration and Status Registers tab?

Environment

    Intel® Quartus® Prime Design Software
    External Memory Interfaces (EMIF) IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

When Traffic Generator 2.0 (TG2) Toolkit for the Intel Agilex® 7  DDR4 IP is configured such that TG_USER_WORM_EN = 1, TG_RETURN_TO_START_ADDR = 1, TG_ADDR_MODE = random or random-sequential, and TG_WRITE/READ_REPEAT_COUNT > 1, the Intel Agilex® 7  DDR4 IP Traffic Generator 2.0 (TG2) Toolkit failure signal will be incorrectly asserted.

Resolution

This problem is planned to be fixed starting with the Intel® Quartus® Prime Pro Edition Software version 20.4 onwards.

 

 

1