Article ID: 000094549 Content Type: Troubleshooting Last Reviewed: 08/15/2023

Why does an AXI-Lite non-word-aligned register access to the PTP packet classifier within the Ethernet Subsystem Intel® FPGA IP fail to function properly?

Environment

    Intel® Quartus® Prime Pro Edition
    Interfaces
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 23.1, non-word-aligned register accesses to the PTP packet classifier within the Ethernet Subsystem Intel® FPGA IP will fail to complete properly. 

Resolution

There is no workaround for this problem. You should ensure that all register accesses to the packet classifier are performed to word-aligned addresses.
This problem has been fixed in version 23.2 of the Intel® Quartus® Prime Pro Edition Software.
 

Related Products

This article applies to 1 products

Intel Agilex® 7 FPGAs and SoC FPGAs F-Series

1