Article ID: 000094218 Content Type: Error Messages Last Reviewed: 04/03/2023

Info(208543): No frame error detected in device <n>.

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

You might see this message when reading the EMR after injecting errors into Intel® Stratix® 10 or Intel Agilex® 7 FPGAs using the Fault injection Debugger if you have not enabled the "Allow SEU fault injection" option in the Intel® Quartus® Prime Pro Edition Software.

Resolution

To avoid this message, enable the "Allow SEU fault injection" option in the Intel® Quartus® Prime Pro Edition Software or manually add the following assignment to your .qsf file:

set_global_assignment -name ALLOW_SEU_FAULT_INJECTION ON