Description
Due to a problem in the Quartus® Prime Pro Edition Software version 22.4 and earlier, you may see the Quartus® Prime Pro Edition Software GUI crashes without any message at the Timing Analysis stage. The problem occurs when the Design Assistant rules RDC-50001 and RDC-50002 are enabled.
Resolution
To work around this problem, follow the steps below:
- Click Assignments > Settings
- Choose Design Assistant Rule Settings, uncheck RDC-50001 and RDC-50002
- Re-run the Timing Analysis stage.
This problem has been fixed from the Quartus® Prime Pro Edition Software Version 23.1.