Article ID: 000094117 Content Type: Troubleshooting Last Reviewed: 12/04/2024

Sourced NativeLink script <Quartus Installation Path>/quartus/common/tcl/internal/nativelink/modelsim.tcl missing"

Environment

  • Intel® Quartus® Prime Lite Edition
  • Questa*-Intel® FPGA Edition
  • Questa*-Intel® FPGA Starter Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® Prime Lite Edition Software version 22.1, you may see the below error message when you try to run the Nativelink simulation flow. 

    Info: Starting NativeLink simulation with Questa Intel FPGA software
    Sourced NativeLink script c:/intelfpga_lite/22.1std/quartus/common/tcl/internal/nativelink/modelsim.tcl missing "
    Error: NativeLink simulation flow was NOT successful

     

     

    Resolution

    To work around the problem, download and replace the qnativelinkflow.tcl file located at the <Intel® Quartus® Installation Path>/quartus/common/tcl/internal/nativelink directory. 
    Relaunch the simulation.

    Download the qnativelinkflow.tcl 

    This problem is fixed beginning with the Quartus® Prime Lite Edition Software version 23.1.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices