Article ID: 000093304 Content Type: Connectivity Last Reviewed: 11/15/2023

Why do I see a restriction on reference clock location with ASIC Proto I/O Standard in PHY Lite for Parallel Interfaces Intel Agilex® 7 FPGA IP?

Environment

  • Intel® Quartus® Prime Pro Edition
  • PHY Lite for Parallel Interfaces Intel® Arria® 10 FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in Intel® Quartus® Prime Pro Edition Sofware version 22.4, the PHY Lite for Parallel Interfaces Intel Agilex® 7 FPGA IP lanes cannot be shared with the reference clock if the ASIC Proto I/O standard is used.

     

     

    Resolution

    To work around this problem in Intel® Quartus® Prime Pro Edition Software version 22.4, specify the reference clock location with either Intel® Quartus® Prime Pro Edition Pin Planner or Intel® Quartus® Prime Pro Edition Assignment Editor.

    This problem has been fixed starting with the Intel® Quartus® Prime Pro Edition Software version 23.1.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs