Article ID: 000092458 Content Type: Error Messages Last Reviewed: 08/09/2023

Internal Error: Sub-system: LBLK, File: /quartus/legality/lblk/lblk_lab_checker.cpp, Line: 716

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.3 and earlier, you might see this internal error during the fitter stage of compilation. The internal error only occurs in designs with one or more non-rectangular Logic Lock regions. This internal error only occurs on some seeds.

    Resolution

    To work around this problem, either rerun the fitter with a new seed number or remove the non-rectangular Logic Lock region.

    This problem has been fixed starting with Intel® Quartus® Prime Pro Edition Software version 22.4.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices