Article ID: 000092384 Content Type: Product Information & Documentation Last Reviewed: 11/27/2023

Why does Intel® Quartus® Prime Pro Edition Software Fitter report a VCCIO_PIO_SDM voltage for Intel Agilex® 7 devices that differ from the 3A bank voltage?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    According to the Intel Agilex® 7 Device Family Pin Connection Guidelines, the 3A bank power supply and VCCIO_PIO_SDM should be connected together.

    However, due to a problem in the Intel® Quartus® Prime Pro Edition Software, the Fitter .pin report will report the voltage of the 3A bank correctly. Still, the voltage of VCCIO_PIO_SDM does not match it.

     

     

     

    Resolution

    You should follow the Intel Agilex® 7 Device Family Pin Connection Guidelines in accordance with the conditions of your design.

    This problem will be resolved in a future release of the Intel® Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs