Article ID: 000091471 Content Type: Error Messages Last Reviewed: 08/16/2023

Fatal Error: Segment Violation: faulting address=0x8, PC=0x7f0d85c89714 : 0x7f0d85c89714: periph_fpp!FPP_CELL::add_link(FPP_LINK const&) + 0x4

Environment

  • Intel® Quartus® Prime Pro Edition
  • High Bandwidth Memory (HBM2) Interface Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.2 and earlier, you might see the following error when compiling Intel® Stratix® 10 designs containing the High Bandwidth Memory (HBM2) Interface Intel® FPGA IP:

    Fatal Error: Segment Violation: faulting address=0x8, PC=0x7f0d85c89714 : 0x7f0d85c89714: periph_fpp!FPP_CELL::add_link(FPP_LINK const&) + 0x4

    This error might occur if the reference clocks for the HBM2 intellectual property (IP) are set as virtual pins.

    Resolution

    To work around this error, ensure that the reference clocks for the HBM2 IP do not have a virtual pin assignment.

    This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition Software.