Article ID: 000091471 Content Type: Error Messages Last Reviewed: 08/16/2023

Fatal Error: Segment Violation: faulting address=0x8, PC=0x7f0d85c89714 : 0x7f0d85c89714: periph_fpp!FPP_CELL::add_link(FPP_LINK const&) + 0x4

Environment

    Intel® Quartus® Prime Pro Edition
    High Bandwidth Memory (HBM2) Interface Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.2 and earlier, you might see the following error when compiling Intel® Stratix® 10 designs containing the High Bandwidth Memory (HBM2) Interface Intel® FPGA IP:

Fatal Error: Segment Violation: faulting address=0x8, PC=0x7f0d85c89714 : 0x7f0d85c89714: periph_fpp!FPP_CELL::add_link(FPP_LINK const&) + 0x4

This error might occur if the reference clocks for the HBM2 intellectual property (IP) are set as virtual pins.

Resolution

To work around this error, ensure that the reference clocks for the HBM2 IP do not have a virtual pin assignment.

This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition Software.

Related Products

This article applies to 1 products

Intel® Stratix® 10 FPGAs and SoC FPGAs

1