Article ID: 000091463 Content Type: Compatibility Last Reviewed: 05/25/2023

Can I re-run the Assembler to generate the SRAM Object File (SOF) for Intel® Stratix® 10 and Intel Agilex® 7 FPGAs when changing the configuration scheme from Active Serial to Avalon® streaming x8, x16 or x32 without recompiling the full design?

Environment

    Intel® Quartus® Prime Pro Edition
    Intel® FPGA Programming Software

UNIX family*, Windows® 10 family

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

No, re-running the Assembler in the Intel® Quartus® Prime Pro Edition Software is not sufficient because Active Serial (AS) x4 and Avalon® streaming x8, x16, x32 configuration schemes have different sets of reserved configuration pins in the Intel® Stratix® 10 and Intel Agilex® 7 FPGAs.

 

 

Resolution

Recompile the full design using the Intel® Quartus® Prime Pro Edition Software according to the respective FPGA configuration schemes.