Article ID: 000091390 Content Type: Troubleshooting Last Reviewed: 01/11/2023

Why does accessing an invalid register address on the AXI-Lite management bus of the MACsec Intel® FPGA IP cause the bus to hang?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Interfaces
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.2, access to an invalid address on the AXI-Lite management bus of the MACsec Intel® FPGA IP will cause the bus to hang.

    Resolution

    To work around this problem in the Intel® Quartus® Prime Pro Edition Software v22.2, do not attempt to access invalid (unspecified) register addresses on the AXI-Lite bus.
    This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition software.

    Related Products

    This article applies to 1 products

    Intel® Agilex™ 7 FPGAs and SoC FPGAs I-Series

    Disclaimer

    1

    All postings and use of the content on this site are subject to Intel.com Terms of Use.