Article ID: 000090609 Content Type: Troubleshooting Last Reviewed: 11/15/2024

Why does the Agilex™ FPGA EMIF simulation log have additional CALBUS messages?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® Prime Pro Edition Software version 22.1, you may see these additional CALBUS messages during the simulation of the Agilex™ FPGA EMIF:

    ....

              4IOSS CALBUS Read -- addr=12107, data=00000000

              4IOSS CALBUS Read -- addr=06107, data=00000000

              4IOSS CALBUS Read -- addr=12107, data=00000000

              4IOSS CALBUS Read -- addr=06107, data=00000000

              4IOSS CALBUS Read -- addr=06108, data=00000060

              4IOSS CALBUS Read -- addr=06103, data=00000000

              4IOSS CALBUS Read -- addr=06107, data=00000000

              4IOSS CALBUS Read -- addr=12107, data=00000000

              4IOSS CALBUS Read -- addr=12108, data=00000060

    ....

     

    Resolution

    To disable those messages, revert to the previous IOSSM as described here:

    External Memory Interfaces Agilex™ FPGA IP User Guide

    This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.