Article ID: 000090420 Content Type: Error Messages Last Reviewed: 04/11/2023

Error(12418): Termination logic option is set to Series 50 Ohm without Calibration for output pin <pin name>~pad, but setting is not supported by I/O standard 3.0-V LVCMOS

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.1, this error may occur when 3VIO and HPS IP are used simultaneously for designs targeting Intel® Stratix10® devices because "OUTPUT_TERMINATION OFF" assignment is missed to be enabled.

     

    Resolution

    To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 22.1,  add the .qsf assignment "set_instance_assinment -name OUTPUT_TERMINATION OFF -to <pin>" for failed pins.

    This problem has been fixed in the Intel® Quartus® Prime Pro Edition Software version 22.2.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs