Article ID: 000088403 Content Type: Error Messages Last Reviewed: 04/05/2023

Error: Part name AUTO is illegal

Environment

    Intel® Quartus® Prime Pro Edition
    Intel® Acceleration Stack for Intel® FPGA PAC D5005 - Development IAS-D5005-Development
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Acceleration Stack for Development Version 2.0.1, you may see the error above when you create a new component using Platform Designer in the Intel® FPGA Programmable Acceleration Card (Intel® FPGA PAC) D5005.  

This problem occurs due to reduced set of files for the stratix.qdz package.

Resolution

To workaround this problem, download the Intel® Stratix® 10 device support (stratix10-19.2.0.57.qdz) package for the Intel® Quartus® Prime Pro Edition Software v19.2 from the Download Center for FPGAs. 

To add the Intel Stratix 10 device support package to the Intel Quartus Prime Software, click on: Tools > Install Devices.

 

This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software 22.4.

Related Products

This article applies to 2 products

Intel® Stratix®
Intel® FPGA PAC D5005

1