Article ID: 000088318 Content Type: Error Messages Last Reviewed: 04/18/2022

Internal Error: Sub-system: CDB_ATOM, File: /quartus/db/cdb_atom/cdb_atom_sys.cpp, Line: 3000

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software v21.3 and earlier, you might see the following error during the fitter stage when a core design partition assignment exists on a level of hierarchy that contains periphery components:

Internal Error: Sub-system: CDB_ATOM, File: /quartus/db/cdb_atom/cdb_atom_sys.cpp, Line: 3000

 

Resolution

To work around this problem, ensure that core design partition assignments are applied to levels of hierarchy that only contain core logic.

This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software version 22.2.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1