Article ID: 000088113 Content Type: Error Messages Last Reviewed: 10/27/2021

Why do I get a fatal error when running Timing Analysis (Signoff)?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.2 and earlier, you may see a fatal error during Timing Analysis (Signoff) or when running the check_timing command in Timing Analyzer. This problem occurs when analyzing clocks for Design Assistant rule checks.

    Resolution

    To work around this problem, disable the following Design Assistant Rules

    • CLK-30036 to CLK-30042
    • TMC-20011 to TMC-20004

    This problem is fixed beginning with version 21.3 of the Intel® Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices