Article ID: 000087811 Content Type: Troubleshooting Last Reviewed: 04/18/2022

Why are DFE taps adapted values incorrect in the P-Tile Debug Toolkit ?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.2, the DFE tap values reported in the P-Tile Debug Toolkit are incorrect.
It is always -128 for DFE tap 1 and 0 for DFE tap2 to tap5.

Resolution

A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition Software version 21.2.

Download and install patch 0.23 from the following links:

This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.3.

Related Products

This article applies to 2 products

Intel Agilex® 7 FPGAs and SoC FPGAs F-Series
Intel® Stratix® 10 DX FPGA

1