Article ID: 000087732 Content Type: Troubleshooting Last Reviewed: 11/25/2024

Why do I get "ERROR: Detected x mismatches - stopping" during simulation using the Siemens* ModelSim* Simulator?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Native Fixed Point DSP Intel® Stratix® 10 FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Siemens* ModelSim* Simulator v2021.2 and earlier, you may observe this error when simulating the Native Fixed-Point DSP Stratix® 10 FPGA IP Core if you run the "msim_setup.tcl" simulation script and use the "elab" option.

     

    Resolution

    To work around this problem use the "elab_debug" option or use “vsim -voptargs=+acc $elabcommand”.

    This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.
     

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices