Due to a problem in the Intel® Quartus® Prime Pro Edition Software v19.2 and 19.3 on Ubuntu operating system (OS), the result may not be available in the Result Panel of the DSE II after successfully running the compilation.
You may also see the following info messages:
Info: No panels found that match the given pattern (try recompiling): ^Timing Analyzer\|\|(Slow|Fast)\s.*Model\|\|(Slow|Fast)\s.*Model\sFmax\sSummary$
Info: No panels found that match the given pattern (try recompiling): ^Timing Analyzer\|\|(Slow|Fast)\s.*Model\|\|(Slow|Fast)\s.*Model\sSetup\sSummary$
Info: No panels found that match the given pattern (try recompiling): ^Timing Analyzer\|\|(Slow|Fast)\s.*Model\|\|(Slow|Fast)\s.*Model\sHold\sSummary$
Info: No panels found that match the given pattern (try recompiling): ^Timing Analyzer\|\|(Slow|Fast)\s.*Model\|\|(Slow|Fast)\s.*Model\sRecovery\sSummary$
Info: No panels found that match the given pattern (try recompiling): ^Timing Analyzer\|\|(Slow|Fast)\s.*Model\|\|(Slow|Fast)\s.*Model\sRemoval\sSummary$
Info: No panels found that match the given pattern (try recompiling): Fitter\|\|(Resource Section|Place Stage)\|\|Fitter Resource Usage Summary
This is due to the library file libccl_durl_drl.so had been deactivated by the Intel® Quartus® Prime Software installer for Ubuntu systems to fix a internal error during the Intel® Quartus® Prime Software GUI startup.
To workaround this problem, go to the <quartus root>/quartus/linux64/ folder and rename the file libccl_curl_drl.so.bak to libccl_curl_drl.so
This problem is fixed beginning with version 21.1 of the Intel® Quartus® Prime Pro Edition Software.