Article ID: 000087209 Content Type: Troubleshooting Last Reviewed: 12/03/2013

50G Interlaken MegaCore Function User Guide Erroneously Indicates MetaFrameLength Can Be Less Than 128 64-Bit Words

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

According to the 50G Interlaken MegaCore Function User Guide, the Meta frame length in words parameter can have a value of 64 8-byte words. However, this is incorrect. The minimum value this parameter can have is 128 8-byte words.

Resolution

This issue has no workaround.

This issue is fixed in version 13.1 Arria 10 Edition of the 50G Interlaken MegaCore Function User Guide.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1