Article ID: 000087001 Content Type: Error Messages Last Reviewed: 02/25/2013

Internal Error: Sub-system: SIN, File: /quartus/tsm/sin/sin_micro_tnodes_dag.cpp, Line: 626 Invalid branch: <OCT setting>

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus II software version 12.1, you may see this internal error when running the Quartus® II PowerPlay Power Analyzer for designs that use parallel on chip termination (OCT) settings other than 50 ohm. This problem affects designs targeting Arria® V and Cyclone® V devices.

The power model does not yet include the parallel OCT settings other than 50 ohm. Thus the 20, 25, 30, 40, 60, and 120 ohm parallel OCT settings are not supported in the Power Analyzer or the Early Power Estimator (EPE) version 12.1.

Resolution

To avoid the internal error when running the Power Analyzer, temporarily set the parallel OCT for the 50 ohm setting. This will allow you to obtain power estimation results for the remainder of your design.

The power model is updated beginning with the Quartus II software version 12.1 SP1 to include all of the supported parallel OCT settings.

Related Products

This article applies to 11 products

Cyclone® V SX SoC FPGA
Cyclone® V GT FPGA
Cyclone® V GX FPGA
Arria® V GX FPGA
Arria® V GZ FPGA
Arria® V SX SoC FPGA
Arria® V GT FPGA
Cyclone® V ST SoC FPGA
Arria® V ST SoC FPGA
Cyclone® V E FPGA
Cyclone® V SE SoC FPGA