Critical Issue
According to the RapidIO II MegaCore Function User Guide, the RapidIO II IP core can be programmed with up to 16 TX Maintenance translation windows. However, the IP core can be programmed with a maximum of two TX Maintenance windows.
This issue has no workaround. Ensure you program only two TX Maintenance windows in your RapidIO II IP core. Attempts to program registers at offsets 0x10110 to 0x101FC have no effect.
This issue is fixed in version 14.0 of the RapidIO II MegaCore Function User Guide.