Article ID: 000086997 Content Type: Troubleshooting Last Reviewed: 06/30/2014

RapidIO II MegaCore Function User Guide Claims Wrong Number of TX Maintenance Windows

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

According to the RapidIO II MegaCore Function User Guide, the RapidIO II IP core can be programmed with up to 16 TX Maintenance translation windows. However, the IP core can be programmed with a maximum of two TX Maintenance windows.

Resolution

This issue has no workaround. Ensure you program only two TX Maintenance windows in your RapidIO II IP core. Attempts to program registers at offsets 0x10110 to 0x101FC have no effect.

This issue is fixed in version 14.0 of the RapidIO II MegaCore Function User Guide.