Article ID: 000086990 Content Type: Troubleshooting Last Reviewed: 11/28/2011

POS-PHY Level 4 MegaCore Function IP Toolbench has an Error After Changing the Device Family

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    If you change the device family when editing an existing custom megafunction variation (POS-PHY Level 4 MegaCore function variation) without first changing the device family in the Quartus II project, an error may occur when generating the MegaCore function. This results in a MegaCore function generation error message.This issue also applies when creating a new custom megafunction variation, if you use a different device family to that specified in the Quartus II project.

    Resolution

    Before using the MegaWizard Plug-In Manager to create or edit a POS-PHY Level 4 custom megafunction variation, make sure that a Quartus II project exists and that the required device family is set in the project. To set the device family, in the Quartus II software, on the Assignments menu click Device.

    When using the MegaWizard Plug-In Manager to create or edit the megafunction variation, set the device family to be the same as the device family set in the Quartus II project. You can set the device family in the Basic Parameters tab when parameterizing the MegaCore function.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices