Article ID: 000086854 Content Type: Install & Setup Last Reviewed: 10/22/2019

Why does IP generation fail for some IP cores in Intel® Quartus® Prime Standard 19.1?

Environment

  • Intel® Quartus® Prime Standard Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to missing Perl libraries  in the Intel® Quartus® Prime Standard Edition software version 19.1, you may see various errors when generating some Platform Designer IP Cores.

     

    Error and Info messages indicating missing Perl library:

    Error: " Failed to find modelu  

    Error: qsys-generate failed with exit code 1

    Info: Can't locate Getopt/Long.pm

     

    Resolution

    A patch is available to fix this problem for the Intel® Quartus® Prime Standard Edition software version 19.1. Download and install Patch from the appropriate link below. 

    Download patch Intel® Quartus® Prime Standard 19.1 Patch 0.01 for Windows (.exe)  

    Download patch Intel® Quartus® Prime Standard 19.1 Patch 0.01  for Linux (.run)

    Download the Readme for Intel® Quartus® Prime Standard 19.1 Patch 0.01 (.txt) 

    Related Products

    This article applies to 5 products

    Intel® Cyclone®
    Intel® Arria®
    Intel® MAX® CPLDs and FPGAs
    Stratix® IV FPGAs