Article ID: 000086749 Content Type: Troubleshooting Last Reviewed: 11/14/2024

Why are MT25QL128, MT25QL01G and MT25QL02G flash devices missing from the Remote Update FPGA IP configuration device list in the Quartus® Prime Software version 18.1?

Environment

  • Intel® Quartus® Prime Standard Edition
  • Remote Update Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a known problem in Quartus® Prime Standard Software version 18.1, Micron* flash devices MT25QL128, MT25QL01G and MT25QL02G are not listed in the Remote Update FPGA IP configuration device list.

    Resolution

    To work around this problem, select a Macronix* flash part with the same density in the configuration device list of the Remote Update FPGA IP but do not check the “Enable reconfig POF checking” option. 

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices