Article ID: 000086702 Content Type: Troubleshooting Last Reviewed: 02/13/2023

Why do I get reconfiguration error with Intel® Cyclone® V, Arria® V, and Stratix® V devices when the POF check option is enabled in the Remote Update IP?

Environment

    Intel® Quartus® Prime Standard Edition
    Remote Update Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

When you instantiate the Remote Update IP with the EPCQ-A device and have the POF Check option enabled, reconfiguration of your Intel® Cyclone® V, Arria® V, and Stratix® V device may fail.

Resolution

Use EPCS instead of EPCQ-A with the same density when instantiating the Remote Update IP.

This problem is fixed starting with the Intel® Quartus® Prime Standard Edition Software version 19.1.”

 

Related Products

This article applies to 3 products

Stratix® V FPGAs
Cyclone® V FPGAs and SoC FPGAs
Arria® V FPGAs and SoC FPGAs

1