Article ID: 000086630 Content Type: Troubleshooting Last Reviewed: 06/13/2024

Why does the Stratix® 10 device failed to configure with the RSU application image?

Environment

    Intel® Quartus® Prime Pro Edition
    Generic Component
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

You may observe "Error code:  0xF004C002" in SDM Debug Toolkit while performing Remote System Update (RSU) to an application image compiled in Quartus® Prime Pro Edition Software version 21.1 with a decision firmware compiled in version prior to 21.1.

Resolution

To work around this issue, there are 2 options to update the decision firmware in flash:

 

a. Update decision firmware Factory image

quartus_pfg –c <input.sof> <output.rpd> -o mode=ASx4 rsu_upgrade=ON

OR

b. Update decision firmware only

quartus_pfg –c <input.sof> <output.rpd> -o mode=ASx4 rsu_upgrade=ON –o firmware_only=1

 

For detailed guideline of updating the decision firmware and Factory image, refer to Stratix® 10 Configuration User Guide or Stratix® 10 Hard Processor System Remote System Update  User Guide.

Related Products

This article applies to 1 products

Intel® Stratix® 10 FPGAs and SoC FPGAs

1