Article ID: 000086607 Content Type: Troubleshooting Last Reviewed: 05/09/2018

Why does the Intel® Stratix® 10 Chip ID IP core read all zeros in user mode?

Environment

    Intel® Quartus® Prime Pro Edition
    Chip ID Intel® Stratix® 10 FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

When the Intel® Stratix® 10 Chip ID IP core is taken out of reset in user mode, you may see no output on the 'chip_id' port even after the assertion of 'data_valid' signal. This may be seen with designs compiled in Intel Quartus® Prime Pro software version 17.1. 

Resolution

To read out the unique chip ID from Intel Stratix 10 devices

  • Assert reset initially to reset the chip ID IP core.
  • Trigger a high -> low transition on the 'readid' port to initiate one read command to the IP core.
  • Use the 'readid' port to trigger multiple reads in user mode.

This problem has been fixed in Intel Quartus Prime Pro software version 18.0.

Related Products

This article applies to 1 products

Intel® Stratix® 10 FPGAs and SoC FPGAs

1