Article ID: 000086583 Content Type: Troubleshooting Last Reviewed: 11/16/2012

Why Qsys pick the wrong parameters value of FIR Compiler II and create an error message when generate the Qsys system?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

You may receive the following error message when your Qsys design consist of more than one FIR Compiler II and which are located at difference Qsys subsystem with difference parameter.

Error: fir_compiler_ii_0: Port ast_sink_data has width 32 in TCL, but 16 in the design file

This issue is causing by FIR Compiler II using global variables to avoid re-querying parameters. This works fine if there is just a single instance of FIR complier II.

Resolution

To fix this issue, all of the global variables in the HP_FIR_HW.tcl file have to removed and this will officially fixed in version 12.1.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1