Article ID: 000086432 Content Type: Troubleshooting Last Reviewed: 08/14/2018

Physical placement assignments made in the Intel® Quartus® Prime Pro Edition software version 17.1 may change for certain Intel® Stratix® 10 E-tile devices if migrating to production

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In the Intel® Quartus® Prime Pro software version 17.1 if your design include location assignments that use X-Y coordinate (such a LogicLock regions or physical location assignments) for Intel® Stratix® 10 devices with transceiver E-tile, you must increase the X coordinate by 8 if you want to migrate the same assignments to the corresponding production ordering code.

    The following device ordering codes are affected:

          1ST280EY2F55E2VGI1

          1ST280EY3F55E3VGI1

          1ST280EY1F55E1VGI1

          1SX280HU1F50E2VGS1

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs

    Disclaimer

    1

    All postings and use of the content on this site are subject to Intel.com Terms of Use.