Article ID: 000086066 Content Type: Error Messages Last Reviewed: 11/14/2024

Error (297009): Can't open project -- you do not have permission to write to all the files or create new files in the project's

Environment

    Intel® Quartus® Prime Lite Edition
    Intel® Quartus® Prime Standard Edition
    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime Standard and Pro Edition Software version 17.0 and earlier you may see the error message mentioned above happened intermittently if you attempt to compile multiple designs in the same directory.

Resolution

To work around the problem, go to

Assigment -> settings -> Compilation Process Settings -> select Maximum Processors allow = 1

This problem is fixed starting with the Quartus® Prime Standard and Pro Edition Software version 17.1.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1