Description
The dual-clock FIFO function does not currently support Showahead mode when
using a synchronous FIFO. You are using a synchronous FIFO when the parameter
CLOCKS_ARE_SYNCHRONIZED = "TRUE". This parameter is set to "TRUE"
when you answer "Yes" to the "Do you want the FIFO to pipeline its output flags"
question on page 3 of the FIFO MegaWizard.
Environment
BUILT IN - ARTICLE INTRO SECOND COMPONENT