Article ID: 000085554 Content Type: Troubleshooting Last Reviewed: 08/23/2016

Can I share an RZQ pin between multiple external memory interfaces placed in the same I/O column in an Arria 10 device?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

No. Starting from Quartus® Prime software version 16.0, sharing RZQ pins in an Arria® 10 device between multiple external memory interfaces will cause a fitter error of type:
Error (18656): RZQ pin "<oct_rzqin_signal>" connects to multiple OCT blocks in user-mode. Merging user-mode OCT is not supported.

Resolution

In earlier Quartus software versions, the fitter supported RZQ sharing.
If you are migrating a design that shares an RZQ pin, contact Altera.

The recommended placement for the RZQ pin is in the address/command I/O bank because this minimizes local variations in the OCT calibration.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1