Due to a problem in the Quartus® II software version 12.1 and later, you may see this error in Stratix® V devices when using the ALTLVDS_TX megafunction in external PLL mode.
Error: SERDES transmitter node 'lvds_tx:lvds_tx_inst0|altlvds_tx:ALTLVDS_TX_component|lvds_tx_lvds_tx:auto_generated|outclock_tx' is not properly connected on the 'ENABLE0' port. It must be connected to one of the valid ports listed below.Info: Can be connected to LOADEN port of stratixv_pll_lvds_output WYSIWYGInfo: Can be connected to OUTCLK port of generic_pll WYSIWYG
To workaround this problem an LVDS buffer needs to be inserted between the external pll and the ALTLVDS instance on the tx_inclock and the tx_enable ports.
Refer to the related solution below to learn how you can add an intermediate LVDS buffer between the external PLL and ALTLVDS IP.