Article ID: 000085205 Content Type: Troubleshooting Last Reviewed: 09/09/2013

Why does the SignalTap II Logic Analyzer Node Finder not display any signals?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

This problem can occur if you have different capitalization between the Project Navigator and the Node Finder. The hierarchy name are case sensitive and different case will represent different hierarchy path. If this is true, no matches are displayed in Nodes Found window when you list node in SignalTap™ II Logic Analyzer Node Finder.

Resolution

To avoid this problem, correct the mismatch in capitalization by re-selecting the top-level hierarchy in your Quartus® II project. To do this, perform the following steps:

  1. Open the Settings dialog box from the Assignment menu
  2. Select the General category
  3. Click on ... to browse the list of modules
  4. Select the correct top-level entity from the Select Entity dialog box.
  5. Click OK to save your changes
  6. Recompile your design

The Node Finder should now be able to find signals successfully.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1