Article ID: 000084787 Content Type: Error Messages Last Reviewed: 10/14/2014

Error: " Use clock enable for output ports are unavailable while output ports are not registered."

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

Due to a problem in the Quartus® II software version 14.0 Arria 10 Edition, you may see this error if you change the option from Two read/write ports to One read port and one write port using the same parameter editor. This problem affects any designs that use One read port and one write port with Use clock enable for output registers even though the output port is already registered.

Resolution

To work around this problem, close the RAM: 2-PORT IP parameter editor, then reopen it.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1