Article ID: 000084668 Content Type: Troubleshooting Last Reviewed: 11/22/2017

In Quartus Prime Pro Edition software version 16.0, Import Design is not compatible with Project Clean

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

In Quartus Prime Pro Edition software version 16.0, Project > Clean Project is not compatible with Project > Import Design. If you run Import Design, the project will fail with Error(23035): Tcl error: ERROR: Cannot open project: aram.

Resolution

To workaround this issue:

  1. Do not use Project > Clean Project with Project > Import Design. Instead, use the Overwrite option from the Import Design menu or command line argument.
  2. If Clean Project was called, you can select Close project followed by Open project in the GUI before calling Import Design; this fixes the invalid state.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1