Critical Issue
If a RapidIO II IP core receives an incoming restart-from-retry control
symbol immediately followed by a start-of-packet control
symbol, the IP core processes these control symbols in the wrong
order. As a result, the IP core does not recognize the following end-of-packet control
symbol as legitimate. When the end-of-packet control
symbol arrives, the IP core enters the Input Error state
and sends a packet-not-accepted control symbol to the
RapidIO link partner.
Although the IP core recovers through the normal error recovery process, the recovery process takes time. Therefore, this issue causes lost bandwidth.
This issue has no workaround.
This issue will be fixed in a future version of the RapidIO II IP core.